  electronic contactors and motor controllers product overview and selection guide longer lasting smoother running industrial controls
2 ci-tronic stands for high performance and long life there are many ways to control a heating process or a motor, but you?l have a hard time finding a better way than with danfoss ci-tronic components. the ci-tronic concept represents a breakthrough in contactor technology. in effect, we?e revolutionized the solid state relay to create a range of electronic contactors and motor controllers that are as simple to use as they are advanced. on the one hand, ci-tronic contactors are as easy to specify and install as ordinary electro-mechanical components. on the other, they provide the switching speed of a solid state relay, yet thanks to their unique design outlast conventional ssrs by a factor of 10. the secret? at the heart of every ci-tronic component is a new power chip that eliminates the thermal problems which cause early burnouts in traditional ssrs. we call the technology ?te,?for low thermal expansion, but bottom line for you is significantly greater reliability and operational life. danfoss ci-tronic contactors are ideal for just about any type of industrial heating appli- cation, while ci-tronic motor controllers can be used on everything from conveyors to cranes. just as important, like all danfoss controls, ci-tronic components come with our usual assurance of global availability, fair prices, volume supply and fast delivery. and, of course, responsive service, if needed. ci-tronic components set high standards for quality and reliability, but you?l also be impressed by the sheer scope of the product range. it includes both electronic contactors and analog power controllers as well as soft starters, torque limiters, reversing contactors and other types of motor controllers. moreover, ci-tronic contactors already comply with iec/en 60947-4-3, the coming eu standard that will put tight new controls on ambient and operating temperatures and emc immunity and emission. electronic contactors eci electronic contactors aci analogue power controllers motor controllers mci motor controllers (soft starters) mci mci b soft starter with brake tci starting torque limiters mci dol motor contactors rci reversing contactors able of contents introduction 2 electronic contactors 4 electronic contactors eci-1 6 electronic contactors eci-2 8 electronic contactors eci-3 10 analogue power controllers aci 12 motor controllers 14 motor controllers mci 16 motor controllers with brake mci b 18 starting torque limiters tci 20 motor contactors mci dol 22 reversing contactors rci 24 common information 26 a new standard across a whole product range t
in conventional power relays, excessive heat generated by the power chip can lead to metal fatigue due to the different thermal expansion rates between the chip, the heat conductor and the current clip. in addition, air pockets in the soldering create hot spots on the chip, which can also impair performance and cause breakdowns. lte technology solves the problem in a unique way to give you a high quality product with extremely long life: new materials virtually eliminate the effects of thermal expansion in the power chip new design with fewer soldering points increases heat dissipation new one-shot vacuum soldering process prevents the formation of air pockets and hot spots and they?e as easy to specify and install as ordinary contactors contactors and motor controllers play a relatively small if crucial role in most processes, so why should choosing the right component be so complicated. you?l find ci-tronic components refreshingly easy to work with ?as simple to specify and install as standard electro-mechanical devices and vastly easier to deal with than conventional ssrs. it only takes a moment to configure them, and there? no need for heat sinks or varistors. ci-tronic components can be dimensioned to their full rated power and are delivered as a completely engineered product featuring: compact modular construction din-rail mountable design industry standard ratings universal control voltages led status indicators logical control settings gate control voltage chip power current heat spreader dcb ceramic heat flow heatsink copper trimetal ceramic aluminum solder the ci-tronics power chip consists of a silicon device soldered in a sandwich construction between a current clip and a heat conductor assembly. the chip allows current to flow when a control voltage is applied to the gate. thermal glue lte technology takes the heat off our power chip 3
ci-tronic tm means fewer burnouts, better process control, longer heater life it can happen to any oem. you deliver a large and expensive system to a customer far from home. one day there? a breakdown and an urgent call for help. a service rep is dispatched to solve the problem only to find a burned out contactor in the heater sys- tem ?a small fault but one that ends up costing you time, money, maybe even a little goodwill. whether you?e producing equipment for injec- tion molding, die casting, shrink wrapping or baking, constant operation eventually takes its toll on your heat control switch. naturally, you can help avoid the unexpected by choosing contactors that are reli- able. but you can also make contactor replacement an even rarer occurrence by equipping your system with ci-tronic tm components. ci-tronic contactors are purpose-built for demanding industrial applications ?or applications where you just don? want to risk that unexpected call in the night. with lte technology, burnouts due to thermal stress become a very remote concern. ci-tronic contactors outlast solid state relays by a factor of 10 and outperform electro-mechanical contactors by an even wider margin. and they?e price competitive, too. ci-tronic products also gives you better control of your heating process and longer heater life. control is improved by the use of faster switching patterns which provide more stable process tempera- tures, which in turn reduces thermal stress and extends heater life. 400 300 200 100 0,1 1 10 100 life cycles at full load (x1,000,000) price index ci-tronic contactors outlast solid state relays by a factor of 10 electro-mechanical contactors traditional solid state relays ci-tronic contactors 4 electronic contactors
electro- mechanical contactors the low switching rates of electro- mechanical contac- tors cause wide temperature swings, resulting in poor process control and reduced heater life. voltage voltage temperature temperature time time electronic contactors ci-tronic contactors permit fast switch- ing frequencies, giving you far better control of the heat- ing process, fewer temperature fluctua- tions and reduced stress on the heater. 5 ci-tronic tm also simplifies purchasing and logistics use ci-tronic components for a wide range of applica- tions including electric heaters, infrared lamps, frequent switching valves, soft starting of transformers, welding machines and other equipment. they switch single and three-phase heaters up to 50 amps. use ci-tronic products worldwide. they?e designed for line voltages up to 600 v a.c., feature a universal control voltage, and automatically adjust to 50/60 hz operation. soldering of sensitive electronic components requires the precise control provided by ci-tronic technology. the dependability and long life of our components makes them ideal for heating applications in the plastics industry. accurate control of baking temperatures with ci-tronic compo- nents helps ensure a quality product. robust design makes ci-tronic contactors a wise choice for welding applications. > < < << heater heater process process
6 single-phase electronic contactors type eci-1 general type eci 15-1 eci 30-1 eci 50-1 product description eci electronic contactors are designed for applications demanding fast and precise switching. the contactors utilize scr power chips with new lte (low thermal expansion) technology. this unique power chip design ensures high switching capacity and long life. the contactors are burst fired for reduced emc emission, have led status indicators and accept universal control voltages. the units are din-rail mountable, complete with heat sink and require no additional components. typical applications eci electronic contactors are designed for fast and demanding switching of loads such as heaters, solenoids , transformers and motors design standard iec/en 60947-4-3 approvals ce, csa and nrtl/c output specifications operational current ac-1, ac-51 (heater load) 15 a 30 a 50 a ac-3, ac-53a (motor load) 15 a 1 15 a 15 a operational voltage (50/60 hz) 24 - 230 v a.c. 24 - 480 v a.c. 24 - 600 v a.c. leakage current max. 1 ma minimum operational current 10 ma semiconductor protection fusing type 1 co-ordination 50 a gl/gg 50 a gl/gg 50 a gl/gg type 2 co-ordination 1800 a 2 s 1 (16 a gl/gg) 1800 a 2 s 1800 a 2 s thermal specifications and environment power dissipation, continuous duty 1.2 w/a power dissipation, intermittent duty 1.2 w/a duty cycle ambient temperature range -5 to 40 ? cooling method natural convection mounting vertical (see also general mounting instructions) max. ambient temperature with limited current 60 c, see derating for high temperatures in chart below storage temperature range -20 to 80 c protection degree/pollution degree ip 20/3 insulation specifications rated insulation voltage, u i 660 v rated impulse withstand voltage, u imp 4 kv installation category iii control specifications control voltage (+/- 10%) 5 - 24 v d.c. / 24 - 230 v a.c./d.c. pick-up voltage 4.25 v d.c. / 20.4 v a.c./d.c. drop-out voltage 1.5 v d.c. / 7.2 v a.c./d.c. control current/power max. 15 ma at 4 v d.c. / 1.5 va/6 ma at 24 v d.c. response time max. 1 / 2 cycle / 1 cycle emc immunity meets requirements of en 50082-1 and en 50082-2 1) contactors designed for 600 v: max. ac-3 load: 10 a max. type 2 co-ordination fuse: 450 a 2 s features scr power chip with lte technology compact modular design complete with heat sink din-rail mountable built-in varistor protection operational current up to 50 a (ac-1) line voltage up to 600 v a.c. universal control voltage burst firing (zero cross) led status indicator ip 20 protection problem-free specification according to industry standard easy and quick installation
ambient eci 15 eci 30 eci 50 temperature 40 ? 15 a 30.0 a 50.0 a 50 ? 12.5 a 25.0 a 40.0 a 60 ? 10 a 20.0 a 30.0 a 7 if the contactor is placed inside small cabinets, care must be taken to avoid exceeding the max. ambient temperature. otherwise the current must be derated according to table. functional diagram wiring diagram heater load wiring diagram motor load operating at high temperatures operational current 24-230 v a.c. 24-480 v a.c. 24-600 v a.c. max. ac-1 control voltage dimensions type code no. code no. code no. 15 a 5-24 v d.c. 22.5 mm module eci 15-1 037n0063 037n0065 037n0067 15 a 24-230 v a.c./d.c. 22.5 mm module eci 15-1 037n0064 037n0066 037n0068 30 a 5-24 v d.c. 45 mm module eci 30-1 037n0007 037n0009 037n0011 30 a 24-230 v a.c./d.c. 45 mm module eci 30-1 037n0001 037n0003 037n0005 50 a 5-24 v d.c. 90 mm module eci 50-1 037n0008 037n0010 037n0012 50 a 24-230 v a.c./d.c. 90 mm module eci 50-1 037n0002 037n0004 037n0006 selection guide operational voltage mains voltage (l1) control voltage (a1, a2) load voltage (t1) led for further information on dimensions, mounting and temperature overload protection see common information, page 26. control voltage control voltage
dual-phase electronic contactors type eci-2 general type eci 30-2 eci 50-2 product description eci electronic contactors are designed for applications demanding fast and precise switching. the contactors utilize scr power chips with new lte (low thermal expansion) technology. this unique power chip design ensures high switching capacity and long life. the contactors are burst fired for reduced emc emission, have led status indicators and accept universal control voltages. the units are din-rail mountable, complete with heat sink and require no additional components. typical applications eci electronic contactors are designed for fast and demanding switching of loads such as heaters, solenoids , transformers and motors design standard iec/en 60947-4-3 approvals ce, csa and nrtl/c output specifications operational current, ac-1, ac-51 (heater load) 30 a accumulated 50 accumulated ac-3, ac-53a (motor load) 15 a accumulated 15 accumulated operational voltage (50/60 hz) 24 - 230 v a.c. 24 - 480 v a.c. 24 - 600 v a.c. leakage current max. 1 ma minimum operational current 10 ma semiconductor protection fusing type 1 co-ordination 50 a gl/gg 50 a gl/gg type 2 co-ordination 1800 a 2 s 1800 a 2 s thermal specifications and environment power dissipation, continuous duty 1.2 w/a (per phase) power dissipation, intermittent duty 1.2 w/a duty cycle (per phase) ambient temperature range -5 to 40 ? cooling method natural convection mounting vertical (see also general mounting instructions) max. ambient temperature with limited current 60 c, see derating for high temperatures in chart below storage temperature range -20 to 80 c protection degree/pollution degree ip 20/3 insulation specifications rated insulation voltage, u i 660 v rated impulse withstand voltage, u imp 4 kv installation category iii control specifications control voltage (+/- 10%) 5 - 24 v d.c. / 24 - 230 v a.c./d.c. pick-up voltage 4.25 v d.c. / 20.4 v a.c./d.c. drop-out voltage 1.5 v d.c. / 7.2 v a.c./d.c. control current/power max. 15 ma at 4 v d.c. / 1.5 va/6 ma at 24 v d.c. response time max. 1 / 2 cycle / 1 cycle emc immunity meets requirements of en 50082-1 and en 50082-2 features scr power chip with lte technology compact modular design complete with heat sink din-rail mountable built-in varistor protection operational current up to 50 a (ac-1) line voltage up 600 v a.c. universal control voltage burst firing (zero cross) led status indicator ip 20 protection problem-free specification according to industry standard easy and quick installation 8
if the contactor is placed inside small cabinets, care must be taken to avoid exceeding the max. ambient temperature. otherwise the current must be derated according to table. operating at high temperatures operational current 24-230 v a.c. 24-480 v a.c. 24-600 v a.c. max. ac-1 1 control voltage dimensions type code no. code no. code no. 30 a 5-24 v d.c. 45 mm module eci 30-2 037n0019 037n0021 037n0023 30 a 24-230 v a.c./d.c. 45 mm module eci 30-2 037n0013 037n0015 037n0017 50 a 5-24 v d.c. 90 mm module eci 50-2 037n0020 037n0022 037n0024 50 a 24-230 v a.c./d.c. 90 mm module eci 50-2 037n0014 037n0016 037n0018 1) rated as the maximum sum of current in l1 and l2 selection guide operational voltage 9 functional diagram mains voltage (l1) control voltage (a1, a2) load voltage (t1) led 1 ambient eci 30 eci 50 temperature 40 ? 30.0 a 50.0 a 50 ? 25.0 a 40.0 a 60 ? 20.0 a 30.0 a mains voltage (l2) control voltage (a3, a4) load voltage (t2) led 2 wiring diagram 2 single-phase loads wiring diagram three-phase load for further information on dimensions, mounting and temperature overload protection see common information, page 26. control voltage 1 control voltage control voltage 2
10 three-phase electronic contactors type eci-3 general type eci 10-3 eci 20-3 product description eci electronic contactors are designed for applications demanding fast and precise switching. the contactors utilize scr power chips with new lte (low thermal expansion) technology. this unique power chip design ensures high switching capacity and long life. the contactors are burst fired for reduced emc emission, have led status indicators and accept universal control voltages. the units are din-rail mountable, complete with heat sink and require no additional components. typical applications eci electronic contactors are designed for fast and demanding switching of loads such as heaters, solenoids , transformers and motors design standard iec/en 60947-4-3 approvals ce, csa and nrtl/c output specifications operational current, ac-1, ac-51 (heater load) 10 a 20 a ac-3, ac-53a (motor load) 10 a 10 a operational voltage, 3 phase 24 - 230 v a.c. (50/60 hz) 24 - 480 v a.c. 24 - 600 v a.c. leakage current max. 1 ma minimum operational current 10 ma semiconductor protection fusing type 1 co-ordination 35 a gl/gg 35 a gl/gg type 2 co-ordination 450 a 2 s 450 a 2 s thermal specifications and environment power dissipation, continuous duty 3 w/a power dissipation, intermittent duty 3 w/a duty cycle ambient temperature range -5 to 40 ? cooling method natural convection mounting vertical (see also general mounting instructions) max. ambient temperature with limited current 60 c, see derating for high temperatures in chart below storage temperature range -20 to 80 c protection degree/pollution degree ip 20/3 insulation specifications rated insulation voltage, u i 660 v rated impulse withstand voltage, u imp 4 kv installation category iii control specifications control voltage (+/- 10%) 5 - 24 v d.c. / 24 - 230 v a.c./d.c. pick-up voltage 4.25 v d.c. / 20.4 v a.c./d.c. drop-out voltage 1.5 v d.c. / 7.2 v a.c./d.c. control current/power max. 15 ma at 4 v d.c. / 1.5 va/6 ma at 24 v d.c. response time max. 1 / 2 cycle / 1 cycle emc immunity meets requirements of en 50082-1 and en 50082-2 features scr power chip with lte technology compact modular design complete with heat sink din-rail mountable built-in varistor protection operational current up to 20 a (ac-1) line voltage up 600 v a.c. universal control voltage burst firing (zero cross) led status indicator ip 20 protection problem-free specification according to industry standard easy and quick installation
if the contactor is placed inside small cabinets, care must be taken to avoid exceeding the max. ambient temperature. otherwise the current must be derated according to table. operating at high temperatures operational current 24-230 v a.c. 24-480 v a.c. 24-600 v a.c. max. ac-1 control voltage dimensions type code no. code no. code no. 10 a 5-24 v d.c. 45 mm module eci 10-3 037n0031 037n0033 037n0035 10 a 24-230 v a.c./d.c. 45 mm module eci 10-3 037n0025 037n0027 037n0029 20 a 5-24 v d.c. 90 mm module eci 20-3 037n0032 037n0034 037n0036 20 a 24-230 v a.c./d.c. 90 mm module eci 20-3 037n0026 037n0028 037n0030 selection guide operational voltage functional diagram mains voltage (l1, l2, l3) control voltage (a1, a2) load voltage (t1, t2, t3) led ambient eci 10 eci 20 temperature 40 ? 10.0 a 20.0 a 50 ? 8.0 a 16.0 a 60 ? 6.5 a 13.0 a 11 wiring diagram heater load (ac-1, ac-51) wiring diagram motor load for further information on dimensions, mounting and temperature overload protection see common information, page 26. control voltage control voltage
12 a nalogue power controllers type aci general type aci 30-1 aci 50-1 product description the versatile aci analogue power controller is designed for very precise temperature and transformer control . due to the built-in micro-computer the controller can operate in phase angle as well as in burst firing control method. the controller automatically adapts to the load to ensure a smooth inrush, and in burst-firing mode it will further eliminate the unwanted effects of dc magnetizing on transformers. the aci unit is easily connected to a plc/regulator by means of one of the selectable input signals. typical applications analogue control of heaters and infrared lamps. the aci controller is also ideal on transformer controlled processes. design standard iec/en 60947-4-3 approvals ce output specifications operational current ac-1 (heater load) 30 a 50 a ac-56a (transformer load) 30 a 50 a operational voltage 208 - 230 v a.c. 400 - 480 v a.c control method phase angle control selectable linear power or linear voltage burst firing control selectable cycle time: 0.- 60 seconds leakage current max. 1 ma minimum operational current 10 ma semiconductor protection fusing type 1 co-ordination 50 a gl/gg 50 a gl/gg type 2 co-ordination 1800 a 2 s 1800 a 2 s thermal specifications and environment power dissipation, continuous duty 1.2 w/amp. power dissipation, intermittent duty 1.2 w/amp. duty cycle ambient temperature range -5 to 40 ? cooling method natural convection mounting vertical (see also general mounting instructions) max. ambient temperature with limited current 60 c, see derating for high temperatures in chart below storage temperature range -20 to 80 c protection degree/pollution degree ip 20/3 insulation specifications rated insulation voltage, u i 660 v rated impulse withstand voltage, u imp 4 kv installation category iii control specifications control supply voltage 19- 28 v a.c./d.c. control signals: current loop control 4-20 ma, 20-4 ma, 0-20 ma and 20-0 ma (voltage drop < 3 v) voltage control 0-10 v d.c. and 10-0 v d.c. (input resistance > 300 k ? ) potentiometer control 0-10 k ? and 10-0 k ? isolation: control inputs floating control input voltage line to control 2.5 kv a.c. voltage supply to control 500 v a.c. protection supply and control inputs are protected against overload and over voltage emc immunity meets requirements of en 50082-1 and en 50082-2 features scr power chip with lte technology compact modular design complete with heat sink din-rail mountable built-in varistor protection accepts current loop, voltage and potentiometer control inputs selectable phase angle and burst firing control method micro-computer controlled for maximum performance built-in emc filter led status indicator ip 20 protection problem-free specification according to industry standard easy and quick installation
ambient aci 30 aci 50 temperature 40 ? 30.0 a 50.0 a 50 ? 25.0 a 40.0 a 60 ? 20.0 a 30.0 a 13 control methods & function burst firing mode principle wiring diagram operational current 208-230 v a.c. 400-408 v a.c. max. ac-1 supply voltage dimensions type code no. code no. 30 a 19-28 v a.c./d.c. 45 mm module aci 30-1 037n0057 037n0059 50 a 19-28 v a.c./d.c. 90 mm module aci 50-1 037n0058 037n0060 selection guide operational voltage adj. cycle time 0.4-60 seconds automatic load adaptation 100 % power function 0 min. max. input signal phase angle mode principle automatic load adaptation 100 % power or voltage function 0 min. max. input signal for further information on dimensions, mounting and temperature overload protection see common information, page 26. if the controller is placed inside small cabinets, care must be taken to avoid exceeding the max. ambient temperature. otherwise the current must be derated according to table. operating at high temperatures control signals supply voltage
motor controllers 14 ci-tronic tm also represents an affordable breakthrough in motor controls soft starters are a tested way to keep torque surges in ac motors from damaging the equipment they?e meant to control ?nothing new about that. what is new, however, is that now there? an affordable line of these controls designed specifically for smaller motors ?the ci-tronic range from danfoss. ci-tronic motor controllers cover the power range from 0.1 to 15 kw. they?e ideal for applications that require smooth starting and stopping but that don? call for the expense of a conventional soft starter. use them on pumps, fans, conveyors, gear or belt-driven machinery and countless other types of equipment. they provide precise control while reduc- ing the shocks and vibrations that are a major cause of equipment failure and downtime. in addition, by reducing inrush currents during motor startup they eliminate power dropouts that can damage sensitive electronic equipment, saving you the expense of having to reinforce the line. there are also a variety of ci-tronic controllers for more specialized tasks. for example, our motor contactors and reversing contactors are ideal for applications with frequent starts and stops. a zero cross-switching technique is used (the contactor always switches when the voltage is zero) to ensure speed and accuracy. these reliable products provide long service on everything from automatic doors to thread cutting machines and are an effective way to control difficult functions like ?nching?on cranes. finally, for less demanding applications it? hard to beat our starting torque limiters, which offer the dependability of ci-tronic technology at highly attractive prices. ci-tronic motor controllers can be adjusted precisely for the needs of your application. ramp-up and ramp-down times can be set from 0.5 -10 seconds. starting torque can be adjusted from 0-85% of nominal torque. and for appli- cations with high breakaway torque the controller can provide a kickstart of full torque for 200 ms.
15 everyone benefits regardless of the application, ci-tronic motor controllers provide smooth and precise starting and stopping while reducing wear and tear on your equipment. but they also benefit individual applications in specific ways. conveyors and packaging equipment smooth operation prevents tilting and spills less stress on belts/chains prevents snapping/breakage long life on indexing and reversing unlimited start/stop automatic doors smooth opening and closing faster operation cranes no rough stops when clutch brake is engaged no gearbox damage due to operator inching fans no belt squirreling or snapping reduced number of belts pumps no water hammering no damaged piping due to pressure peaks compressors reduced starting current eliminates line voltage drop tooling machines long life on indexing fast reversing
16 motor controllers type mci features individual adjustable acceleration and deceleration times, 0.5-10 seconds initial torque adjustable from 0-85% breakaway function (kick start) universal control voltage: 24-480 v a.c./d.c. automatic detection of missing phases automatic adaptation to 50/60 hz led status indicator built-in varistor protection unlimited start/stop operations per hour optional aux. contacts ip 20 protection compact din rail mountable design general type mci 3 mci 15 mci 25 product description the digital controlled mci soft starter are designed for smooth control of 3 phase ac motors. the mci controller has individually adjustable acceleration and deceleration times. thanks to the adjustable initial torque and the unique breakaway (kick start) function the controller can be optimized for almost any application typical applications ac motor application where a smooth start and/or stop is advantageous, such as conveyors, fans, pumps, comp ressors and high inertia loads. mci controllers are also obvious as replacement of star/delta starters design standard iec/en 60947-4-2 approvals ce, ul, ul-c and csa output specifications operational current ac 3, ac 53a and ac 58a (motor load) 3 a 15 a 25 a motor size at: 208 - 230 v a.c. 0.1- 0.7 kw (0.18-1 hp) 0.1 - 4.0 kw (0.18-5 hp) 0.1 - 7.5 kw (0.18-10 hp) 400 - 480 v a.c. 0.1 - 1.5 kw (0.18-2 hp) 0.1 - 7.5 kw (0.18-10 hp) 0.1 - 11 kw (0.18-15 hp) 550 - 600 v a.c. 0.1 - 2.2 kw (0.18-3 hp) 0.1 - 7.5 kw (0.18-10 hp) 0.1 - 18kw (0.18-25 hp) leakage current 5 ma a.c. max. minimum operational current 50 ma overload current profile x-tx: 8-3 overload relay trip class class 10 semiconductor protection fusing type 1 co-ordination 25 a gl/gg 50 a gl/gg 80 a gl/gg type 2 co-ordination 72 a 2 s 1800 a 2 s 6300 a 2 s thermal specifications and environment power dissipation, continuous duty 4 w 2 w/a power dissipation, intermittent duty 4 w 2 w/a duty cycle ambient temperature range -5 to 40 ? cooling method natural convection mounting vertical (see also general mounting instructions) max. ambient temperature with limited current 60 c, see derating for high temperatures in chart below storage temperature range -20 to 80 c protection degree/pollution degree ip 20/3 insulation specifications rated insulation voltage, u i 660 v rated impulse withstand voltage, u imp 4 kv installation category iii control specifications control voltage (+/- 10%) 24 - 480 v a.c./d.c. drop-out voltage 5 v a.c./d.c. control current/power max. 15 ma/2 va response time max. 70 ms ramp-up time adjustable 0 - 10 seconds, 0 - 20 seconds on version with aux. contact ramp-down time adjustable 0 - 10 seconds, 0 - 20 seconds on version with aux. contact initial torque adjustable 0 - 85% of nominal torque, with or without ?ick start scr auxialiary contacts (optinal) voltage/current max. 24-480 v a.c./0.5 a (ac-14, ac-15) fuse max. 10 a gl/gg, i 2 t max 72 a 2 s emc immunity meets requirements of en 50082-1 and en 50082-2
1 7 ambient mci 3 mci 15 mci 25 temperature 40 ? 3 a 15 a 25.0 a 50 ? 2.5 a 12.5 a 17.5 a 60 ? 2.0 a 10.0 a 15.0 a operational voltage motor current motor power control voltage dimensions type aux. code no. max. max. contacts 208-230 v a.c. 3 a 0.7 kw/1hp 24-480 v a.c./d.c. 22.5 mm module mci 3 037n0073 15 a 4.0 kw/5.5 hp 24-480 v a.c./d.c. 45 mm module mci 15 037n0037 25 a 7.5 kw/10 hp 24-480 v a.c./d.c. 90 mm module mci 25 037n0038 25 a 7.5 kw/10 hp 24-480 v a.c./d.c. 90 mm module mci 25 i-0, by-pass 037n0069 400-415 v a.c. 3 a 1.5 kw/2 hp 24-480 v a.c./d.c. 22.5 mm module mci 3 037n0074 440-480 v a.c. 3 a 1.5 kw/2 hp 24-480 v a.c./d.c. 22.5 mm module mci 3 037n0084 400-480 v a.c. 15 a 7.5 kw/10 hp 24-480 v a.c./d.c. 45 mm module mci 15 037n0039 25 a 11 kw/15 hp 24-480 v a.c./d.c. 90 mm module mci 25 037n0040 25 a 11 kw/15 hp 24-480 v a.c./d.c. 90 mm module mci 25 i-0, by-pass 037n0070 550-600 v a.c. 3 a 2.2 kw/3 hp 24-480 v a.c./d.c. 22.5 mm module mci 3 037n0075 15 a 7.5 kw/10 hp 24-480 v a.c./d.c. 45 mm module mci 15 037n0041 25 a 18.5 kw/25 hp 24-480 v a.c./d.c. 90 mm module mci 25 037n0042 25 a 18.5 kw/25 hp 24-480 v a.c./d.c. 90 mm module mci 25 i-0, by-pass 037n0071 selection guide motor full danfoss cti 25- load current m/cti 25mb a circuit breaker code no. 0.1-0.16 047b3140 0.16-0.25 047b3141 0.25-0.4 047b3142 0.4-0.63 047b3143 0.63-1.0 047b3144 1.0-1.6 047b3145 1.6-2.5 047b3153 2.5-4.0 047b3154 4-6.3 047b3155 6-10 047b3156 10-16 047b3157 16-20 047b3158 20-25 047b3159 adjustments control of the motor is achieved by acting on the motor voltage. the motor speed will depend on the actual load on the motor shaft. a motor with little or no load will reach full speed before the voltage has reached its maximum value.the motor controller will read time and torque settings in off state. wiring and functional diagrams motor overload and short circuit protection overload and short circuit protec- tion of the motor is easily achieved by installing a circuit breaker on the supply side of the motor controller. select the circuit breaker from the selection table according to the rated nominal operational current of the motor. for information on prospective short circuit current please refer to data for circuit breaker. time motor voltage ramp-up time 0-10 sec. kick start 200 msec. of maximum torque initial torque up to 85% of nominal torque ramp-down time 0-10 sec. operating at high temperatures if the motor controller is placed inside small cabinets, care must be taken to avoid exceeding the max. ambient temperature. otherwise the current must be derated according to table. for further information on dimensions, mounting and temperature overload protection see common information, page 26. control voltage line voltage (l1, l2, l3) control voltage motor voltage t1, t2, t3 led 1 led 2 aux. contacts: 23-24 by-pass 13-14 i-0 note: auxiliary contacts 13-14 and 23-24 is only abailable on some mci 25 types mci 3 version by-passed in steady-state mode. example 1: soft start with initial torque and soft stop. example 2: soft start with kick start, initial torque and soft stop.
18 motor controllers with brake, type mci 25b features adjustable acceleration time, 0-10 seconds initial torque adjustable from 0-85%, with or without kick start (break-away) adjustable dc injection brake, 0-50 a d.c. fast acting brake mode with automatic motor field reduction automatic stop detection universal control voltage 24-480 v a.c./d.c. slow speed function, 7.5% or 10% of nom. speed scr aux. contacs for external control of by-pass, i-o and mechanical brake. automatic detection of missing phase(s) automatic adaptation to 50 or 60 hz unlimited start and stop per hour ip 20 protection compact din rail mountable design general type mci 25b product description mci 25b motor controller with brake is designed for soft starting and braking of 3 phase ac motors. the digital controlled sof t starter features accurate settings and several monitoring functions. acceleration time and initial torque are along with the br aking torque easily adjusted. during braking the mci 25b will apply a dc current to all the windings of the motor, thus providing a powerful brake function. the automatic stop detection ensures a safe operation. for positioning applications the unique slow speed function can be appli ed. typical applications the mci 25b controller is typically applied on demanding braking applications such as saws, cranes, grindin g machines, automatic doors, etc. design standard iec/en 60947-4-2 approvals ce, csa and nrtl/c output specifications operational current ac 3, ac 53a and ac 58a (motor load) 25 a motor size at: 208 - 230 v a.c. 0.7 - 7.5 kw (1-10 hp) 400 - 480 v a.c. 1- 11 kw (1-15 hp) leakage current 5 ma a.c. max. minimum operational current 50 ma overload current profile x-tx: 8-3 overload relay trip class class 10 semiconductor protection fusing type 1 co-ordination 80 a gl/gg type 2 co-ordination 6300 a 2 s thermal specifications and environment power dissipation, continuous duty 2 w/a power dissipation, intermittent duty 2 w/a duty cycle ambient temperature range -5 to 40 ? cooling method natural convection mounting vertical (see also general mounting instructions) max. temperature with limited current 60 c, see derating for high temperatures in chart below storage temperature range -20 to 80 c protection degree/pollution degree ip 20/3 insulation specifications rated insulation voltage, u i 660 v rated impulse withstand voltage, u imp 4 kv installation category iii control specifications control voltage (+/- 10%) 24 - 480 v a.c./d.c. drop-out voltage 5 v a.c./d.c. control current/power max. 15 ma/2 va response time max. 70 ms ramp-up time adjustable 0 - 10 seconds brake current adjustable 0 - 50 a initial torque adjustable 0 - 85% of nominal torque, with or without ?ick start scr auxialiary contacts voltage/current max. 24-480 v a.c./0.5 a (ac-14, ac-15) fuse max. 10 a gl/gg, i 2 t max 72 a 2 s emc immunity meets requirements of en 50082-1 and en 50082-2
1 9 ambient mci 25 temperature 40 ? 25.0 a 50 ? 17.5 a 60 ? 15.0 a operational voltage motor current motor power control voltage dimensions type code no. max. max. 208-230 v a.c. 25 a 7,5 kw/10 hp 24-480 v a.c./d.c. 90 mm module mci 25 b 037n0061 400-480 v a.c. 25 a 11 kw/15 hp 24-480 v a.c./d.c. 90 mm module mci 25 b 037n0062 selection guide . adjustments wiring and functional diagrams motor overload and short circuit protection overload and short circuit protec- tion of the motor is easily achieved by installing a circuit breaker on the supply side of the motor controller. select the circuit breaker from the selection table according to the rated nominal operational current of the motor. for information on prospective short circuit current please refer to data for circuit breaker. braking torque 0-50 a motor voltage ramp-up time 0-10 sec. kick start selectable initial torque up to 85% of nominal torque slow speed 7.5% or 10% operating at high temperatures if the motor controller is placed inside small cabinets, care must be taken to avoid exceeding the max. ambient temperature. otherwise the current must be derated according to table. for further information on dimensions, mounting and temperature overload protection see common information, page 26. run/brake command slow speed command forced brake command by-pass i-0 or mechanical brake common line voltage (l1, l2, l3) run command slow speed command brake command motor voltage t1, t2, t3 brake on 23-24 by-pass 13-14 i-0 13-14 ( ) aux. contacts: m motor full danfoss cti 25- load current m/cti 25mb a circuit breaker code no. 1.6-2.5 047b3153 2.5-4.0 047b3154 4-6.3 047b3155 6-10 047b3156 10-16 047b3157 16-20 047b3158 20-25 047b3159
s t a r t i n g torque limiters type tci features adjustable ramp-up time, from 0.5 -5 seconds initial torque adjustable from 0 - 85% single and three-phase operation led status indicator built-in varistor protection unlimited start/stop operations per hour ip 20 protection compact din-rail mountable design general type tci 15 tci 25 product description tci starting torque limiters are designed for soft starting of 1 and 3-phase ac motors. the tci unit is easy to install between the motor starter and the motor, and features adjustable ramp-up time and initial torque. typical applications ac motor application where a soft start is required, such as conveyors, fans, compressors and high inertia loads. design standard iec/en 60947-4-2 approvals ce, csa and nrtl/c output specifications operational current ac 3, ac 53a and ac 58a (motor load) 15 a 25 a motor size at: 208 - 240 v a.c. 0.1 - 4.0 kw (0.18-5.5 hp) 0.1 - 7.5 kw (0.18-10 hp) 380- 480 v a.c. 0.1 - 7.5 kw (0.18-10 hp) 0.1 - 11 kw (0.18-15 hp) 550 - 600 v a.c. 0.1 - 10 kw (0.18-10 hp) 0.1 - 18.5 kw (0.18-25 hp) minimum operational current 50 ma overload current profile x-tx: 8-3 overload relay trip class class 10 semiconductor protection fusing type 1 co-ordination 50 a gl/gg 80 a gl/gg type 2 co-ordination 1800 a 2 s 6300 a 2 s thermal specifications and environment power dissipation, continuous duty 1 w/a power dissipation, intermittent duty 1 w/a. duty cycle ambient temperature range 0 to 45 ? cooling method natural convection mounting vertical (see also general mounting instructions) max. ambient temperature with limited current 60 c, see derating for high temperatures in chart below storage temperature range -20 to 80 c protection degree/pollution degree ip 20/3 insulation specifications rated insulation voltage, u i 660 v rated impulse withstand voltage, u imp 4 kv installation category iii control specifications ramp-up time adjustable from 0.5 - 5 seconds initial torque adjustable from 0 - 85% of nominal torque emc immunity meets requirements of en 50082-1 and en 50082-2 20
mains voltage (l1, l2, l3) motor voltage led 1 led 2 operational voltage motor current max. motor power max. dimensions type code no. 208-240 v a.c. 15 a 4.0 kw/5.5 hp 45 mm module tci 15 037N0045 25 a 7.5 kw/10 hp 45 mm module tci 25 037n0046 380-480 v a.c. 15 a 7.5 kw/10 hp 45 mm module tci 15 037N0045 25 a 11 kw/15 hp 45 mm module tci 25 037n0046 550-600 v a.c. 15 a 10 kw/15 hp 45 mm module tci 15 037n0047 25 a 18.5 kw/25 hp 45 mm module tci 25 037n0048 690 v a.c. 25 a 18.5 kw/25 hp 45 mm module tci 25 037n0049 selection guide 21 ambient tci 15 tci 25 temperature 40 ? 15 a 25 a 50 ? 15 a 25 a 60 ? 15 a 20 a wiring and functional diagrams operating at high temperatures if the motor controller is placed inside small cabinets, care must be taken to avoid exceeding the max. ambient temperature. otherwise the current must be derated according to table. motor overload and short circuit protection overload and short circuit protec- tion of the motor is easily achieved by installing a circuit breaker on the supply side of the motor controller. select the circuit breaker from the selection table according to the rated nominal operational current of the motor. for information on prospective short circuit current please refer to data for circuit breaker. single phase operation three phase operation adjustments control of the motor is achieved by acting on the motor volt- age. the motor speed will depend on the actual load on the motor shaft. a motor with little or no load will reach full speed before the voltage has reached its maximum value. 100 % 0time motor voltage ramp-up time 0,5-5 sec. initial torque up to 85% of nominal torque for further information on dimensions, mounting and temperature overload protection see common information, page 26. motor full danfoss cti 25- load current m/cti 25mb a circuit breaker code no. 0.1-0.16 047b3140 0.16-0.25 047b3141 0.25-0.4 047b3142 0.4-0.63 047b3143 0.63-1.0 047b3144 1.0-1.6 047b3145 1.6-2.5 047b3153 2.5-4.0 047b3154 4-6.3 047b3155 6-10 047b3156 10-16 047b3157 16-20 047b3158 20-25 047b3159
22 motor contactors type mci-dol features direct on-line starting long life: ac-3: 25 mill. cycles ac-4: 5 mill. cycles universal control voltage led status indicator built-in varistor protection unlimited start/stop operations per hour ip 20 protection compact din-rail mountable design general type mci 15 dol product description mci-dol electronic motor contactors are designed for fast and demanding switching of 3-phase ac motors. the contactors are burst fired for reduced emc emission, have led status indicators and accept universal control voltages. typical applications cranes, packaging machines and other applications with frequent inching, jogging or plugging and where a hi gh number of operating cycles is essential. design standard iec/en 60947-4-2 approvals ce, csa and nrtl/c output specifications operational current ac 3 (motor load) 15 a ac 4 (motor load, inching, jogging) 15 a motor size at: 208- 240 vac 0.1 - 4.0 kw (0.18-5 hp) 400- 480 vac 0.1 - 7.5 kw (0.18-10 hp) 550- 600 vac 0.1 - 11 kw (0.18-15 hp) leakage current 5 ma a.c. max. minimum operational current 50 ma overload current profile x-tx: 8-3 overload relay trip class class 10 semiconductor protection fusing type 1 co-ordination 50 a gl/gg type 2 co-ordination 1800 a 2 s thermal specifications and environment power dissipation, continuous duty 2 w/a power dissipation, intermittent duty 2 w/a duty cycle ambient temperature range 0 to 40 ? cooling method natural convection mounting vertical (see also general mounting instructions) max. ambient temperature with limited current 60 c, see derating for high temperatures in chart below storage temperature range -20 to 80 c protection degree/pollution degree ip 20/3 insulation specifications rated insulation voltage, u i 660 v rated impulse withstand voltage, u imp 4 kv installation category iii control specifications control voltage (+/- 10%) 24 - 480 v a.c., 24-60 v d.c. drop-out voltage 5 v a.c./d.c. control current/power max. 15 ma / 2 va response time max. 70 ms emc immunity meets requirements of en 50082-1 and en 50082-2
ambient mci 15 temperature 40 ? 15 a 50 ? 12.5 a 60 ? 10.0 a 23 if the unit is placed inside small cabinets, care must be taken to avoid exceeding the max. ambient temperature. otherwise the current must be derated according to table. motor overload and short circuit protection overload and short circuit protection of the motor is easily achieved by installing a circuit breaker on the supply side of the motor controller. select the circuit breaker from the selection table according to the rated nominal operational current of the motor. for information on prospective short circuit current please refer to data for circuit breaker. operating at high temperatures motor full load current danfoss cti 25m/cti 25mb a circuit breaker code no. 0.1-0.16 047b3140 0.16-0.25 047b3141 0.25-0.4 047b3142 0.4-0.63 047b3143 0.63-1.0 047b3144 1.0-1.6 047b3145 1.6-2.5 047b3153 2.5-4.0 047b3154 4-6.3 047b3155 6-10 047b3156 10-16 047b3157 operational voltage motor current motor power control voltage dimensions type code no. max. max. 208-240 v a.c. 15 a 4.0 kw/5.5 hp 24-480 v a.c./24-60 v d.c. 45 mm module mci 15 dol 037n0054 400-480 v a.c. 15 a 7.5 kw/10 hp 24-480 v a.c./24-60 v d.c. 45 mm module mci 15 dol 037n0055 550-600 v a.c. 15 a 11 kw/15 hp 24-480 v a.c./24-60 v d.c. 45 mm module mci 15 dol 037n0056 selection guide mains voltage (l1, l2, l3) control voltage (a1, a2) load voltage (t1, t2, t3) led 2 wiring and functional diagrams for further information on dimensions, mounting and temperature overload protection see common information, page 26. control voltage
24 r e versing contactors type rci features compact modular design complete with heat sink din-rail mountable built-in varistor protection operational current up to 10 a (ac-3) line voltage up 480 v a.c. built-in interlock universal control voltage burst firing (zero cross) led status indicator ip 20 protection problem-free specification according to industry standard easy and quick installation general type rci 10 product description rci reversing contactors are designed for demanding forward/reverse control of 3-phase ac motors. the zero cross-switching method ensures very fast and precise motor control and virtually eliminates emc emission. the rci reversing contactor is ideal where fast switching capability and long life are essential. typical applications conveyors, thread cutting machines, packaging lines and other applications where fast reversing capabilitie s are needed. design standard iec/en 60947-4-2 approvals ce, csa and nrtl/c output specifications operational current ac-3 (motor load) 10 a ac-4 (motor load, inching, jogging) 8 a motor size at: 208 - 240 v a.c. ac-3: 0.1-2.2 kw (0.18-3 hp) ac-4: 0.1-1.5 kw (0.18-2 hp) 400 - 480 v a.c. ac-3: 0.1-4 kw (0.18-4 hp) ac-4: 0.1-3 kw (0.18-4 hp) leakage current max. 5 ma minimum operational current 50 ma semiconductor protection fusing type 1 coordination 35 a gl/gg type 2 coordination 450 a 2 s thermal specifications and environment power dissipation, continuous duty 1.2 w/a power dissipation, intermittent duty 1.2 w/a duty cycle ambient temperature range -5 to 60 ? cooling method natural convection mounting vertical (see also general mounting instructions) storage temperature range -20 to 80 c protection degree/pollution degree ip 20/3 insulation specifications rated insulation voltage, u i 660 v rated impulse withstand voltage, u imp 4 kv installation category iii control specifications control voltage (+/- 10%) 5 - 24 v d.c . / 24 - 230 v a.c./d.c. pick-up voltage 4.25 v d.c. / 20.4 v a.c./d.c. drop-out voltage 1.5 v d.c. / 7.2 v a.c./d.c. control current/power max. 25 ma at 24 v d.c. / 6 ma / 1.5 va at 24 v d.c. response time max. 1 / 2 cycle / 1 cycle built in switching delay on forward and reverse, max. 80 m seconds emc immunity meets requirements of en 50082-1 and en 50082-2
2 5 motor overload and short circuit protection overload and short circuit protection of the motor is easily achieved by installing a circuit breaker on the supply side of the motor controller. select the circuit breaker from the selection table according to the rated nominal operational current of the motor. for information on prospective short circuit please refer to data for circuit breaker. motor full load current danfoss cti 25m/cti 25mb a circuit breaker code no. 0.1-0.16 047b3140 0.16-0.25 047b3141 0.25-0.4 047b3142 0.4-0.63 047b3143 0.63-1.0 047b3144 1.0-1.6 047b3145 1.6-2.5 047b3153 2.5-4.0 047b3154 4-6.3 047b3155 6-10 047b3156 wiring and functional diagrams for further information on dimensions, mounting and temperature overload protection see common information, page 26. mains voltage (l1, l2, l3) control voltage (a1, a2) motor forward led f control voltage (a3, a4) motor reverse led r operational voltage motor current max. motor power max. control voltages dimensions type code no. 208-240 v a.c. 10 a 2.2 kw/3 hp 5-24 v d.c. 45 mm module rci 10 037n0044 10 a 2.2 kw/3 hp 24-230 v a.c./d.c. 45 mm module rci 10 037n0043 400-480 v a.c. 10 a 4 kw/5.5 hp 5-24 v d.c. 45 mm module rci 10 037n0044 10 a 4 kw/5.5 hp 24-230 v a.c./d.c. 45 mm module rci 10 037n0043 selection guide control voltage control voltage
temperature overload protection mounting instruction in mm (inches) thermal overload protection of controller wiring of overload protection if unit is mounted horizontally, derate current by 50%. keep heat sink clean. airflow should not be blocked. the thermostat is connected in series with the control circuit of the main contactor. when the temperature of the heat sink exceeds 100 c the main contactor will be switched off. a manual reset is necessary to restart this circuit. optional thermal overload protection is pos- sible by inserting a thermostat in the slot on the right-hand side of the controller. order: up62 thermostat 037n0050 ! common information and dimensions 26
27 dimensions in mm (inches) type aci 15, eci 30, mci 15, tci 15, tci 25, rci 10, and mci 15dol type eci 15, mci 3 type aci 50, eci 50 type mci 25, mci 25b
one call and you?e in control contactors and motor controllers pressure and temperature controls industrial valves one call to danfoss gives you access to an entire range of high-quality industrial controls. the danfoss line encompasses components for industrial monitoring and control systems based on the principles of pressure and temperature measurement, electrical power, and fluid control, and includes: electro-mechanical contactors electronic contactors and motor controllers pressure and temperature switches pressure transmitters temperature sensors and transmitters solenoid valves externally operated valves thermostatically operated valves given their important monitoring and control func- tions, danfoss components are designed for accuracy, reliability and long life. and our determination to guarantee a high-quality product is matched by an equally strong commitment to customer service. a specialist in the danfoss industrial controls group can advise you on product selection and configuration, based on long experience in your industry. you?l find that with sales and service centers in over 100 countries, danfoss is usually only a local call away. industrial controls 520b0736/dkact.pb.c50.a2.02 produced by danfoss g1 advertising agency 00.11.aph.cs-frw.cbc.ao danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. danfoss reserves the right to alter its products without notice. this also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specif ications already agreed. all trademarks in this material are property of the respective companies. danfoss and the danfoss logotype are trademarks of da nfoss a/s. all rights reserved. danfoss limited perivale industrial park horsenden lane south greenford middx. ub6 7qe telephone: 0870 608 0008 telefax: 0870 608 0009


▲Up To Search▲   

 
Price & Availability of 037N0045

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X